INPUT & OUTPUT ELEMENTS

Safety functions for sensor/actuator processing offer considerable simplification in programming. Programming effort for logical/time comparison of multiple inputs of the safety sensor system can be omitted.

Instead, the necessary processing is selected quickly and safely via the periphery configuration menu. In the program editor, each input and output element appears only as a function block, already reduced to a single logic signal.

 DESIGNATIONFUNCTIONPARAMETER
Confirm button1 or 2 input signals, logical and optional time based comparison of the two inputs, optional quit requests after start or activation/monitoring. Reduction to 1 logic signal on the programming editorBreak/make contact function of the input signals, 1 or 2 switching contacts, pulse assignment optional, start monitoring, quit y/n
Emergency stopLogical and optional time based comparison of the two inputs, optional quit request after start/actuation. Reduction to 1 logic output for further processing1 or 2 switching contacts, pulse assignment optional, time monitoring input signals y/n, start monitoring, quit y/n
Door control1, 2 or 3 input signals, logical and optional time based comparison of the input signals, optional quit request after start/open. Reduction to 1 logic output for further processing1, 2 or 3 switching contacts, pulse assignment optional, time monitoring input signals y/n, start monitoring, quit y/n
Two-Hand Control2 or 4 input signals, monitoring of input signals in  accordance to EN 574. Certified function for 2-hand command. Reduction to 1 logic signal for further processing2 make contacts or 2 change-over contacts, pulse assignment
Limit switch1 or 2 input signals, logic and optional time based comparision of the input lines, optional quit demand after start or activation and/or monitored start. Reduction to 1 logic signal on the programming editorbreak/make contact of the input signals, 1 or 2 switching contact, signature (pulse) designation optionally, time based monitoring of input signals y/n, start monitoring y/n, quit y/n 
Light curtain1 or 2 input signals, logical and optional time-based comparison of the two inputs, optional acknowledgement request after start/trigger and monitored start. Reduction to 1 logic output for further processing1 NO contact or 1 change-over contact, pulse assignment optional, time-based monitoring of input signals y/n, start monitoring, quit y/n
Mode switch2 or 3 input signals, logical monitoring of the input signals. Reduction to 2 or 3 outputs2 or 3 input signals, pulse assignment
Sensor Input Element1, 2 or 3 input signals, logical and optional time-based comparison of the two inputs, optional quit request after start/trigger and monitored start. Reduction to 1 logic output for further processing    1, 2 or 3 switching contacts, pulse assignment optional, time monitoring input signals y/n, start monitoring, quit y/n
Safety Mat1 or 2 analog input signals, response threshold selectable, optional quit request after start/trip and monitored start. Reduction to 1 logic signal    1 or 2 analog or digital input signals, response threshold parameterizable, time monitoring input signals y/n, start monitoring, quit y/n
Enabling switchInput of a Deadman's switchPulse assignment optional, start monitoring, 1 or 2 input signals
Start / ResetMonitored input. Enables alarm and/or logic reset.Start monitoring type, logic and/or alarm reset, pulse assignment.
Relay OutOptional connection of 2 relay outputs to safe shutdown channel. Monitoring of external contactors/relays by means of external switching contacts selectable. Reduction of the switching signal to 1 logic signal.Single or combined operation. Monitoring of external switchgear y/n, delay time for external monitoring.
High-/Low SemiconductorOptional connection of 1 pair Hi/Lo each to a safe shutdown channel. Monitoring of external contactors/relays by means of external switching contacts selectable. Reduction of the switching signal to 1 logic signal.Single or combined operation. Monitoring of external switchgear y/n, delay time for external monitoring.
Digital OutSafe digital output. Monitoring of external contactors/relays selectable by means of external switching contacts.Monitoring of external switching devices y/n, delay time for external monitoring