- Products
- BBH Products GmbH EN
- Products
- SMX 132-1R/2/D
SMX 132-1R/2/D
Decentral I/O extension module for the SMXmodular - basic modules
- 14 Digital inputs
- 10 Digital I/Os
- 6 Relay outputs
- 2 Pulse outputs
- 4 Auxiliary outputs
- 2 /4 pn- or pp-switching outputs
- Communication interface (/D) integrated
- Safety controller up to PL e acc. to EN ISO 13849-1 or SIL3 acc. to IEC 61508
-
Characteristics
- Decentralised I/O expansion module
- Decentralised: Communication with base module SMX100-x via communication interface (/D)
- Central: Communication with base module SMX100-x via backplane bus
- Pulse outputs for cross-shorting detection of digital input signals
- External contact monitoring of connected switchgear (EMU)
- Comprehensive diagnostic functions integrated
- Coded status display via front-side 7 segment display and status LEDs
- 10 safe I/O`s - can be configured as inputs or outputs
- Decentralised I/O expansion module
-
-
Safety related characteristic data
Performance Level PL e (EN ISO 13849-1) PFH1 / architecture 9,2 FIT / Kategorie 4 *
1-channel per Rel 20 FIT (max 8)
2-channel per Rel 1,0 FIT (max 4)Safety Integrity Level SIL 3 (IEC 61508) Proof test interval 20 years = max. operating period -
General data
Max. no. of expansion modules - Interface for expansion modules Communication interface (/D) or T-bus connector, pluggable in top-hat rail, RJ-45 (Ethernet) Number of safe digital inputs 14 Number of safe digital outputs - Number of safe digital I/O 10 Number of relay outputs 6 Number of safe analogue inputs - Number of auxiliary outputs 4 Number of pulse outputs (clock outputs) 2 Type of connection Plug-in terminals with spring or screw connection Axis monitoring (Axes / Encoder interfaces) - Encoder interfaces (D-Sub / screw terminals) - * Value applies only to expansion modules
** pn/pp are configurable via SafePLC²
1) Value applies only for extension module. For total assessment in accordance with EN ISO 13849-1 one must use a series connection with the corresponding basic device => PFHLogic = PFHBasic + PFHExtension -
Electrical data
Supply voltage (tolerance) 24 VDC; 2A (-15%, +20%) Fuse X11.1 min. 30 VDC; max. 3,15A X11.2, X13.1 min. 30 VDC; max. 10A Max. Power consumption (logic) SMX132-1R/2/D 5,2W Rated data digital inputs 24 VDC; 20 mA Typ1 acc. to IEC 61131-2 Rated data digital outputs auxiliary outputs 24 VDC; 250mA pulse outputs (clock outputs) 24 VDC; 250mA digital I/O 01 - 05
06 - 1024 VDC; 0,5A
24 VDC; 2A *Rated data relays Normally open DC 13 24 VDC; 2A AC 15 230 VDC; 2A Normally closed (Read back contact) DC 13 24 VDC; 2A * see „Derating outputs“ -
Derating outputs
» Maximum current load based on temperature
» The maximum total current is 10AType of module Outputs Temperature 30°C/50°C SMX1xx/2/x Q 1 - Q 4 2A / 1,8A -
Environmental data
Temperature 0°C … +50°C operation -25°C … +70°C storage and transport Class of protection IP 20 Climatic category 3K3 acc. to DIN EN 60721-3 Min-, Maximum relative humidity (no condensation) 5% - 85% EMC DIN EN 61000-6-2, DIN EN 61000-6-4, DIN EN 61000-6-7,
DIN EN 61800-3, DIN EN 61326-3, DIN EN 62061Operating altitude 2000m -
Mechanical data
Dimension (HxDxW [mm]) SMX132-1R/2/D 100x115x112,5 Weight [g] SMX132-1R/2/D 620 Mounting to snap on top-hat rail Number of T-Bus 5 Min. terminal cross-section / AWG 0,2 mm2 / 24 Max. terminal cross-section / AWG 2,5 mm2 / 12 -
Device interfaces
Interface Description of interface X09 - X14 / X15 - X26 Voltage supply and I/O interface X91 / X92 Decentralised SDDC ETH and SMMC interface -
Voltage supply and I/O interface
X09 Pin 1 - 1.11
2 - 1.12Read back contact relay 1 3 - 2.11
4 - 2.12Read back contact relay 2 X10 Pin 1 - 3.11
2 - 3.12Read back contact relay 3 3 - 4.11
4 - 4.12Read back contact relay 4 X11 Pin 1 - A1.1 Voltage supply device +24 VDC 2 - A1.2 Voltage supply device +24 VDC outputs 3 - A2.1
4 - A2.2Voltage supply device 0 VDC X12 Pin 1 - I13
2 - I14Safe digital inputs 3 - T1
4 - T2Clock outputs X13 Pin 1 - A1.3
2 - A1.4Voltage supply device +24 VDC outputs 3 - A2.3
4 - A2.4Voltage supply device 0 VDC X14 Pin 1 - IQ01
2 - IQ02Safe digital inputs, outputs pp-switching 3 - Y3
4 - Y4Auxiliary outputs X15 Pin 1 - NC
2 - NCno funktion 3 - Y1
4 - Y2Auxiliary outputs X16 Pin 1 - I01
2 - I02
3 - I03
4 - I04Safe digital inputs X19 Pin 1 - Q1.1
2 - Q1.2Safe relay output 1 3 - Q2.1
4 - Q2.2Safe relay output 2 X20 Pin 1 - Q3.1
2 - Q3.2Safe relay output 3 3 - Q4.1
4 - Q4.2Safe relay output 4 X22 Pin 1 - Q5.1
2 - Q5.2Safe relay output 5 3 - Q6.1
4 - Q6.2Safe relay output 6 X23 Pin 1 - IQ03
2 - IQ04
3 - IQ05
4 - IQ06Safe digital inputs, outputs pp-switching X24 Pin 1 - IQ07
2 - IQ08
3 - IQ09
4 - IQ10Safe digital inputs, outputs pp-switching X25 Pin 1 - I05
2 - I06
3 - I07
4 - I08Safe digital inputs X26 Pin 1 - I09
2 - I10
3 - I11
4 - I12Safe digital inputs -
Decentralised SDDC ETH and SMMC interface
Pin assignment female connector
Communication interface (RJ45) Front side Pin Name Description Color X91 / X92 1 TX+ Transmit Data + white-orange 2 TX- Transmit Data - orange 3 RX+ Receive Data + white-green 4 nc not used blue 5 nc not used white-blue 6 RX- Receive Data - green 7 nc not used white-brown 8 nc not used brown Safe Master - Master Communication (SMMC)
SMMC communication enable a secure data exchange of 2 bytes between multiple SDDC masters. Communication takes place without a master for coordinating the data. This means that data exchange between available subscribers is always possible. This principle means that an incomplete or separates network can work in part areas without chnaging the configuration.
Each port can be configured in the SafePLC².
-
Integrated communication interface
General data Decentralised communication interface /D 2x RJ 45 * * optional for SDDC or SMMC
-
Safety related characteristic data
-
-
Extensions
Item
Description Item-No. SMX132-1R/2/D
Decentral I/O expansion module with 10 safe I/Os + relay option
1634 -
Accessories
Item
Description Item-No. SX0300-1
Terminal connector, screw terminals (set), encoded for cabling SMX132-1R/2/D
on request SXxxxx-x
Terminal connector, spring terminals (set), encoded for cabling SMX132-1R/2/D
on request SX0000-9
T-Bus connector voltage-carrying (grey)
1015
-
Extensions
-
Downloads