SMX 132-1/2/D

Decentral I/O extension module for the SMXmodular - basic modules

  • 14 Digital inputs
  • 10 Digital I/Os
  • 2 Relay outputs
  • 2 Pulse outputs
  • 4 Auxiliary outputs
  • 2 /4 pn- or pp-switching outputs
  • Communication interface (/D) integrated
  • Safety controller up to PL e acc. to EN ISO 13849-1 or SIL3 acc. to IEC 61508
  • Characteristics

    • Decentralised I/O expansion module
      • Decentralised: Communication with base module SMX100-x via communication interface (/D)
      • Central: Communication with base module SMX100-x via backplane bus
    • Pulse outputs for cross-shorting detection of digital input signals
    • External contact monitoring of connected switchgear (EMU)
    • Comprehensive diagnostic functions integrated
    • Coded status display via front-side 7 segment display and status LEDs
    • 10 safe I/O`s - can be configured as inputs or outputs
    • Safety related characteristic data
      Performance Level PL e (EN ISO 13849-1)
      PFH1) / architecture

      9,2 FIT / Cat 4

      Safety Integrity Level SIL 3 (IEC 61508)
      Proof test interval 20 years = max. operating period
    • General data
      Max. no. of expansion modules   -
      Interface for expansion modules   Communication interface (/D) or T-bus connector, pluggable in top-hat rail, RJ-45 (Ethernet)
      Number of safe digital inputs   14
      Number of safe digital outputs    
        pp-switching ** 4
        pn-switching ** 2
      Number of safe digital I/O   10
      Number of relay outputs   2
      Number of safe analogue inputs   -
      Number of auxiliary outputs   4
      Number of pulse outputs (clock outputs)   2
      Type of connection   Plug-in terminals with spring or screw connection
      Axis monitoring (Axes / Encoder interfaces)   -
      Encoder interfaces (D-Sub / screw terminals)   -
      * Value applies only to expansion modules
      ** pn/pp are configurable via SafePLC²

      1) Value applies only for extension module. For total assessment in accordance with EN ISO 13849-1 one must use a series connection with the corresponding basic device => PFHLogic = PFHBasic + PFHExtension

    • Electrical data
      Supply voltage (tolerance)     24 VDC; 2A (-15%, +20%)
      Fuse X11.1   min. 30 VDC; max. 3,15A
        X11.2, X13.1   min. 30 VDC; max. 10A
      Max. power consumption (logic)      
        SMX132-1/2/D   5,2W
      Rated data digital inputs     24 VDC; 20 mA Typ1 acc. to IEC 61131-2
      Rated data digital outputs      
        pn-switching   24 VDC; 2A *
        pp-switching   24 VDC; 2A *
        auxiliary outputs   24 VDC; 250mA
        pulse outputs (clock outputs)   24 VDC; 250mA
        digital I/O    
        01 - 05
      06 - 10
        24 VDC; 0,5A
      24 VDC; 2A *
      Rated data relays      
        Normally open DC 13 24 VDC; 2A
          AC 15 230 VDC; 2A
        Normally closed (Read back contact) DC13 24 VDC; 2A
      * see „Derating outputs“
    • Derating outputs

      » Maximum current load based on temperature
      » The maximum total current is 10A

      Type of module Outputs Temperature 30°C/50°C
      SMX1xx/2/x Q 1 - Q 4 2A / 1,8A
    • Environmental data
      Temperature 0°C … +50°C operation
        -25°C … +70°C storage and transport
      Class of protection IP 20
      Climatic category 3K3 acc. to DIN EN 60721-3
      Min-, Maximum relative humidity (no condensation) 5% - 85%
      EMC DIN EN 61000-6-2, DIN EN 61000-6-4, DIN EN 61000-6-7,
      DIN EN 61800-3, DIN EN 61326-3, DIN EN 62061
      Operating altitude 2000m
    • Mechanical data
      Dimension (HxDxW [mm]) SMX132-1/2/D 100x115x90
      Weight [g] SMX132-1/2/D 500
      Mounting   to snap on top-hat rail
      Number of T-Bus   4
      Min. terminal cross-section / AWG   0,2 mm2 / 24
      Max. terminal cross-section / AWG   2,5 mm2 / 12

       

    • Device interfaces

      Interface Description of interface
      X11 - X16 / X21 - X26 Voltage supply and I/O interface
      X91 / X92 Decentralised SDDC ETH and SMMC interface
    • Voltage supply and I/O interface
      X 11
      Pin 1 - A1.1 Voltage supply device +24 VDC
      2 - A1.2 Voltage supply device +24 VDC outputs
      3 - A2.1
      4 - A2.2
      Voltage supply device 0 VDC
      X 12
      Pin 1 - I13
      2 - I14
      Safe digital inputs
      3 - T1
      4 - T2
      Clock outputs
      X 13
      Pin 1 - A1.3
      2 - A1.4
      Voltage supply device +24VDC outputs
      3 - A2.3
      4 - A2.4
      Voltage supply device 0 VDC
      X 14
      Pin 1 - IQ01
      2 - IQ02
      Safe digital inputs, outputs pp-switching
      3 - Y3
      4 - Y4
      Auxiliary outputs
      X 15
      Pin 1 - NC
      2 - NC
      No function
      3 - Y1
      4 - Y2
      Auxiliary outputs
      X 16
      Pin 1 - I01
      2 - I02
      3 - I03
      4 - I04
      Safe digital inputs
      X 21
      Pin 1 - Q1 Output of the pp-switching Q1_PP / pp-switching Q1
      2 - Q2 Output of the pn-switching Q2_PN / pp-switching Q2
      3 - Q3 Output of the pp-switching Q3_PP / pp-switching Q3
      4 - Q4 Output of the pn-switching Q4_PN / pp-switching Q4
      X 22
      Pin 1 - Q5.1
      2 - Q5.2
      Safe relay outputs
      3 - Q6.1
      4 - Q6.2
      Safe relay outputs
      X 23
      Pin 1 - IQ03
      2 - IQ04
      3 - IQ05
      4 - IQ06
      Safe digital inputs, outputs pp-switching
      X 24
      Pin 1 - IQ07
      2 - IQ08
      3 - IQ09
      4 - IQ10
      Safe digital inputs, outputs pp-switching
      X 25
      Pin 1 - I05
      2 - I06
      3 - I07
      4 - I08
      Safe digital inputs
      X 26
      Pin 1 - I09
      2 - I10
      3 - I11
      4 - I12
      Safe digital inputs
    • Decantralised SDDC ETH and SMMC interface

      Pin assignment female connector

      Communication interface (RJ45) Front side
      Pin Name Description Color X91 / X92
      1 TX+ Transmit Data + white-orange
      2 TX- Transmit Data - orange
      3 RX+ Receive Data + white-green
      4 nc not used blue
      5 nc not used white-blue
      6 RX- Receive Data - green
      7 nc not used white-brown
      8 nc not used brown

      Safe Master - Master Communication (SMMC)

      SMMC communication enable a secure data exchange of 2 bytes between multiple SDDC masters. Communication takes place without a master for coordinating the data. This means that data exchange between available subscribers is always possible. This principle means that an incomplete or separates network can work in part areas without chnaging the configuration.

      Each port can be configured in the SafePLC².

    • Integrated communication interface
      General data
      Decentralised communication interface    
        /D 2x RJ 45 *
      * optional for SDDC or SMMC

       

    • Extensions

      Item

      Description Item-No.

      SMX132-1/2/D

      Decentral I/O expansion module with 10 safe I/Os

      1577
    • Zubehör

      Item

      Description Item-No.

      SX0300-1

      Terminal connector, screw terminals (set), encoded for cabling SMX132-1/2/D on request

      SXxxxx-x

      Terminal connector, spring terminals (set), encoded for cabling SMX132-1/2/D on request

      SX0000-9

      T-Bus connector voltage-carrying (grey) 1015