SMX 11/2

Freely programmable modular compact-type safety controller

  • integrated movement monitoring of one axis
  • 3 Encoder interfaces*
  • 14 Digital inputs
  • 2 Relay outputs
  • 2/4 pn- or pp- switching outputs
  • 2 Auxiliary / pulse outputs
  • Safety controller up to PL e acc. to EN ISO 13849-1 or SIL3 acc. to IEC 61508
  • optional: safe/non-safe fieldbus interface
  • Characteristics

    • Extendable up to:
      • max. 42 safe digital inputs,
      • max. 12 safe digital outputs,
      • max. 20 safe digital I/O‘s,
      • max. 9 safe relay outputs,
      • max. 10 auxiliary outputs,
      • max. 1 safe axis
    • Logic processing up to PL e acc. to EN ISO 13849-1 or SIL 3 acc. to IEC 61508
    • Movement monitoring for one axis up to PL e acc. to EN ISO 13849-1 or SIL 3 acc. to IEC 61508
    • Speed monitoring:
    • RPM-monitoring
    • Standstill monitoring
    • Sense of rotation monitoring
    • Safe incremental dimension
    • Emergency Stop monitoring
    • Position monitoring
    • Position range monitoring
    • Trend range monitoring
    • Target position monitoring
    • Freely programmable modular controller for up to 800 IL instructions
    • Logic diagram oriented programming via SafePLC²
    • Pulse outputs for cross-shorting detection of digital input signals
    • External contact monitoring of connected switchgear (EMU)
    • Switchable safe semi-conductor outputs pn-, pp- switching for safety-relevant functions
    • Monitored relay outputs for safety relevant functions
    • Comprehensive diagnostics functions integrated
    • Parameter management for expansion modules in base module
    • Coded status display via front-side 7 segment display and status LEDs
    • Multifunction buttons (quit, start, reset) can be operated from the front side
    • Configurable via SafePLC² über USB serial adapter or Ethernet based field bus
    • Optional: integrated Communication interface :
      • Standard and safe field bus protocols for communication with a higher level controller (PROFIBUS, PROFINET, DeviceNet, CANopen, EtherNET/IP, EtherCAT, Modbus TCP, PROFIsafe, FSoE)
      • Safe cross communication (SMMC) for data exchange between multiple base devices
      • Field bus protocols with the same hardware can be switched with SafePLC²
      • Safe remote I/O communication for data exchange with distributed I/O systems
    • The mechanical structure of SMX11/2 (/x*) is depended on the respective forms of the base module

     

    * Optional: integrated communication interface (/DNM, /DBM)

  • Variants

    • Safety related characteristic data
      Performance Level PL e (EN ISO 13849-1)
      PFH / architecture

      12,6 FIT / Cat 4

      Safety Integrity Level SIL 3 (IEC 61508)
      Proof test interval 20 years = max. operating period
    • General data
      Max. no. of expansion modules   2
      Interface for expansion modules   T-bus connector, pluggable in top-hat trail
      Number of safe digital inputs   14
      Number of safe digital outputs    
        pp-switching ** 4
        pn-switching ** 2
      Number of safe digital I/O   -
      Number of relay outputs   2
      Number of safe analogue inputs   -
      Number of auxiliary outputs   2
      Number of pulse outputs (clock outputs)   2
      Type of connection   Plug-in terminals with spring or screw connection
      Axis monitoring   1
      Encoder interface (D-Sub / Terminals)   1 / 2 *
      Encoder technology (See table Encoder specifications)   D-SUB X31:
      SSI-Absolute, SinCos, Incremental-TTL

      Terminal X23:
      HTL proximity sensor (10kHz)
      * maximum 2 encoder / axis
      ** pn/pp are configurable via SafePLC²
    • Electrical data
      Supply voltage (tolerance)     24 VDC; 2A (-15%, +20%)
      Fuse X11.1   min. 30 VDC; max. 3,15A
        X11.2   min. 30 VDC; max. 10A
      Max. Power consumption (logic)      
        SMX11/2   3,1W
        SMX11/2/x   6,5W
      Rated data digital inputs     24 VDC; 20 mA Typ1 acc. to IEC 61131-2
      Rated data digital outputs      
        pn-switching   24 VDC; 2A *
        pp-switching   24 VDC; 2A *
        auxiliary outputs   24 VDC; 250mA
        pulse outputs (clock outputs)   24 VDC; 250mA
      Rated data relays      
        Normally open DC 13 24 VDC; 2A
          AC 15 230 VDC; 2A
      see „Derating Outputs“
    • Derating outputs

      » Maximum current load based on temperature
      » The maximum total current is 10A

      Type of module Outputs Temperature 30°C/50°C
      SMX1x/2/x Q 1 - Q 4 2A / 1,8A
    • Environmental data
      Temperature 0°C … +50°C operation
        -25°C … +70°C storage and transport
      Class of protection IP 20
      Climatic category 3K3 acc. to DIN EN 60721-3
      Min-, Maximum relative humidity (no condensation) 5% - 85%
      EMC DIN EN 61000-6-2, DIN EN 61000-6-4, DIN EN 61000-6-7,
      DIN EN 61800-3
      Operating altitude 2000m
    • Mechanical data
      Dimensions (HxDxW [mm]) SMX11/2 100x115x45
        SMX11/2/x * 100x115x67,5
      Weight [g] SMX11/2 310
        SMX11/2/x * 410
      Mounting   to snap on top-hat rail
      Number of T-Bus    
        SMX11/2 2
        SMX11/2/x * 3
      Min. terminal cross-section / AWG   0,2 mm2 / 24
      Max. terminal cross-section / AWG   2,5 mm2 / 12

      Specification, see: „ Optional integrated communication interface“

    • Device interfaces

      Interface Description of interface
      X11 - X14 / X21 - X24 / X81 Voltage supply and I/O interface
      COM Diagnostic- and configuration interface
      X91 / X92 Decentralised SDDC ETH and SMMC interface
      X93 / X94 Field bus interfaces
      X23 / X31 Encoder interface
    • Voltage supply and I/O interface
      X 11
      Pin 1 - A1.1 Voltage supply device +24 VDC
      2 - A1.2 Voltage supply device +24 VDC outputs
      3 - A2.1
      4 - A2.2
      Voltage supply device 0 VDC
      X 12
      Pin 1 - I13
      2 - I14
      Safe didigtal inputs
      3 - T1
      4 - T2
      Clock outputs
      X 13
      Pin 1 - UE1+ Voltage supply Encoder +24V DC X31
      2 - UE1- Voltage supply Encoder 0V DC X31
      3 - Y1
      4 - Y2
      Auxiliary outputs
      X 14
      Pin 1 - I01
      2 - I02
      3 - I03
      4 - I04
      Safe digital inputs
      X 21
      Pin 1 - Q1 Output of the pn-switching Q1_PP / pp-switching Q1
      2 - Q2 Output of the pn-switching Q2_PN / pp-switching Q2
      3 - Q3 Output of the pn-switching Q3_PP / pp-switching Q3
      4 - Q4 Output of the pn-switching Q4_PN / pp-switching Q4
      X 22
      Pin 1 - Q5.1
      2 - Q5.2
      Safe relay output
      3 - Q6.1
      4 - Q6.2
      Safe relay output
      X 23
      Pin 1 - I05
      2 - I06
      3 - I07
      4 - I08
      Safe digital inputs
      X 24
      Pin 1 - I09
      2 - I10
      3 - I11
      4 - I12
      Safe digital inputs
      X 81
      Pin 1 - SD_BUS_24V Power supply SD-BUS +24 VDC
      2 - SD_BUS_GND Power supply SD-BUS 0 VDC
      3 - SD_BUS_OUT SD-BUS output
      4 - FUNC_EARTH Funktional Earth
      * only available for field bus variants
    • Diagnostic and configuration interface
      RJ 10, 4-pin
      Pin Description COM
      Front side
      1 GND
      2 RS485-
      3 RS485+
      4 VCCH

      » With existing Ethernet-based fieldbus interface, it can be used as a diagnostic and configuration interface.

    • Decentralised SDDC ETH and SMMC interface

      Pin assignment female connector

      Communication interface (RJ45) Front side
      Pin Name Description Color X91 / X92
      1 TX+ Transmit Data + white-orange  
      2 TX- Transmit Data - orange
      3 RX+ Receive Data + white-green
      4 nc not used blue
      5 nc not used white-blue
      6 RX- Receive Data - green
      7 nc not used white-brown
      8 nc not used brown

      Safe Master - Master Communication (SMMC)

      SMMC communication enable a secure data exchange of 2 bytes between multiple SDDC masters. Communication takes place without a master for coordinating the data. This means that data exchange between available subscribers is always possible. This principle means that an incomplete or separates network can work in part areas without chnaging the configuration.

      Each port can be configured in the SafePLC².

    • Fieldbus interfaces

      Pin assignment female connector

      Ethernet-based fieldbus interface /xNx (RJ45) Front side
      Pin Name Description Color X93 / X94
      1 TX+ Transmit Data + white-orange
      2 TX- Transmit Data - orange
      3 RX+ Receive Data + white-green
      4 nc not used blue
      5 nc not used white-blue
      6 RX- Receive Data - green
      7 nc not used white-brown
      8 nc not used brown

       

      CAN-based fieldbus interface /DBM, /xBM (D-Sub) Front side
      Pin CANopen PROFIBUS DeviceNet  
      1 - - V-
      2 CAN_L - CAN_H
      3 isoGND RXD/TXD-P (b) DRAIN
      4 - CNTR-P CAN_L
      5 - GND V+
      6 - VP (+5V) -
      7 CAN_H - -
      8 - RXD/TXD-N (A) -
      9 - CNTR-N -
    • Optional integrated communication interface

      » Subsequent expansion capability of standard to safe field bus via additional Mini SD card on the back of the module is possible (/xNx and /xBx)
      » Different specifications can be combined

      General data
      Decentralised communication interface    
        /D 2x RJ 45 *
      Fieldbus interface    
        /xN
      /xB
      2x RJ 45 **
      1x Sub-D ***
      Memory Card (safety program)    
        /xxM 1x Mini SD (front side)
      Memory Card (license for safe field bus)    
        /xNx
      /xBx
      1x Mini SD (rear side)
      SD-Bus   plug-in terminals 
      Status LEDs   
      Field bus adress rotary switch     
        /xBx  2
      * optional for SDDC or SMMC
      ** available field buses PROFINET, EtherCAT, Modbus TCP and Ethernet TCP/IP
      *** available field buses PROFIBUS, CANopen and DeviceNet  

       

      Combination options
      /D /DNM /xNM /xxM /DBM /xBM

       

      Fieldbus protocols /DBM /xBM /DNM /xNM
      PROFIBUS x x    
      DeviceNet x x    
      CANopen x x    
      PROFINET     x x
      Ethernet IP     x x
      EtherCAT     x x
      Modbus TCP     x x
      PROFIsafe * x x x x
      FSoE *     x x
      * Specification required in your order

      » The CAN-based and Ethernet-based fieldbus interfaces can be switched via the SafePLC² between the fieldbus protocols

    • Encoder interfaces
      Pin assignment X31 Pin assignment X23
      Pin Inc / Sin/Cos / SSI Front side
      SMX
      Pin Z1 - Z1 / Z2 - Z2 Terminals
      1 n.c. 1 A (Ā) / A (Ā)
      2 GND 2 - - / B (B)
      3 n.c. 3 A (Ā) / A (Ā)
      4 B / COS - / Clk - 4 - - / B (B)
      5 A + / SIN + / Data +    
      6 A - / SIN - / Data -    
      7 n.c.    
      8 B + / COS + / Clk +    
      9 VCC +    
    • Encoder specifications
      Incremental - TTL
        Physical Layer RS-422 compatible
        Measuring signal A/B Track with 90 degree phase difference
        Type of connection D-SUB 9-pole
        Max. frequency of input cycles (X31) 200 kHz
      Sin/Cos
        Physical Layer RS-422 compatible
        Measuring signal A/B Track with 90 degree phase difference
        Standard Mode
        Max. frequency of input cycles (X31) 200 kHz
      SSI-Absolut
        Data interface Serial Synchronous Interface (SSI) with variable data length of 12 - 28 Bit
        Data format Binary, Gray code
        Physical Layer RS-422 compatible
        Type of connection D-SUB 9-pole
        Mode Master or Listener
        SSI-Master operation  
        Clock rate 150 kHz
        SSI-Listener operation  
        Clock rate (X31) 100 kHz ... 200 kHz
        Min. clock pause time 150 μsec
        Max. clock pause time 1 msec
      HTL proximity sensor
        Signal level 24V / 0V
        Max. counting pulse frequency (circuit logic de-bounced) 10 kHz
        Pulse width 50 μsec
        Type of connection (X23) Plug-in terminals with spring or screw connection
      HTL proximity switch - extended monitoring
        Signal level 24V / 0V
        Max. counting frequency (circuit logic de-bounced) 4 kHz
        Physical Layer PUSH / PULL
        Measuring signal A/B Track with 90 degree phase difference
        Type of connection (X23) Plug-in terminals with spring or screw connection 
    • Basic modules

      Item

      Description Item-No.

      SMX11/2

      Basic module with integrated movement monitoring of one axis

      2001

      SMX11/2/D

      Basic module + decentralised communication

      2002

      SMX11/2/DNM

      Basic module + decentralised communication + Ethernet-based field bus interface + Memory Card

      1749

      SMX11/2/DNM-FSoE

      Basic module + decentralised communication + Ethernet-based field bus interface + Memory Card

      2004

      SMX11/2/xNM

      Basic module + Ethernet-based field bus interface + Memory Card

      1750

      SMX11/2/xNM-FSoE

      Basic module + Ethernet-based field bus interface + Memory Card

      2005

      SMX11/2/xxM

      Basic module + Memory Card

      2006

      SMX11/2/DBM

      Basic module + decentralised communication + CAN-based field bus interface + Memory Card

      1751

      SMX11/2/xBM

      Basic module + CAN-based field bus interface + Memory Card

      1752
    • Accessories

      Item

      Description Item-No.

      SMX91

      Programming cable SMX

      1010

      SXxxxx-x

      Terminal connector, screw terminals (set), encoded for cabling SMX11/2

      on request

      SXxxxx-x

      Terminal connector, spring terminals (set), encoded for cabling SMX11/2

      on request

      SX0000-9

      T-Bus connector volltage-carrying (grey)

      1015

      SXxxxx-x

      Y-cable for encoder splitting

      on request

      FSoE License

      Field bus license for FSoE

      2366

      PROFIsafe License

      Field bus license for PROFIsafe

      2319
    • Extensions

      Item

      Description Item-No.

      SMX31/2

      I/O expansion module

      1705

      SMX31R/2

      I/O expansion module with relay option

      2046

      SMX31R-4/2

      I/O expansion module with relay option

      2047
    • Software

      Item

      Description Item-No.

      SafePLC² 1st

      Programming software, 1st License incl. Hardlock

      1244

      SafePLC² 2nd

      Programming software, 2nd License incl. Hardlock

      1646

      SafePLC² 3rd

      Programming software, 3rd License incl. Hardlock

      1647